The American Society for Testing and Materials (ASTM) has four tests in place for cross-linked polyethylene tanks. All are intended to ensure that the tank’s materials and composition meet the safety standards necessary for operational chemical storage tanks.
One of those tests, the ASTM Gel Test, is an accurate indication of the amount of cross-linked resin in a polyethylene tank. Having a storage tank that can’t pass the ASTM gel test means having a storage system prepared to fail, so let’s take a closer look at the gel test and how to understand its results.
The ASTM 1998 gel test is performed after a tank is molded; we cut a small sample out of the innermost 1/8” of the tank wall. We use a piece of the interior tank wall because that part of the tank interacts with the chemical, and is what needs to be structurally able to withstand the effects of chemical interaction. The piece of the tank goes through the following process:
What is left is the weight of the cross-linked resin material only.
By doing a simple percentage calculation of the remaining weight of the tank sample, we are able to get a reading on the tank’s structural integrity. The ASTM Gel Test, requires that the percentage of cross-linked resin in a polyethylene tank must be 60% or greater at the innermost 1/8” of the tank wall. Anything less is unacceptable and would result in a structurally unsound tank.
It is important to uphold ASTM standards so that the material of a polyethylene chemical storage tank system is strong and ready to effectively store the chemical it is designed for.